Quick answer
In Western Australia, the rules apply before a home is sold, rented, hired or offered as a short-term rental: alarms must be working, in date and wired to mains power. A 10-year battery alarm is only allowed in limited cases.
What the law says in Western Australia
- When the rules apply: Before a home is sold, rented, hired or offered as a short-term rental
- Power: Permanently wired to mains power
- 10-year battery alarms: Only where there’s no hidden space to run wiring, or with council approval
- Age: Not past the maker’s expiry date (or under 10 years old)
- Interconnection: Required where more than one alarm is needed (permits from 1 May 2015)
- Sensor: Photoelectric isn’t required by law; DFES recommends it
- Fines: Up to $5,000; $1,000 infringement notice
WA applies the 2025 National Construction Code to new building work from 1 May 2026, with a 12-month transition. No new smoke alarm rule is announced.
Where the smoke alarms go
- in the places the Building Code required when the alarms were installed; and
- for homes with a building permit from 1 May 2015, interconnected where more than one alarm is needed.
Owner-occupiers who aren’t selling or renting don’t have a retrofit duty under these rules, but DFES still recommends working alarms in every home.
Hardwired or 10-year battery?
- Mains power is the rule: alarms must be permanently wired to the home’s electricity.
- 10-year non-removable battery alarms are allowed only where there’s no hidden space to run wiring and no suitable other spot (for example, a concrete ceiling), or where the local council approves.
- Replaceable 9V battery alarms don’t meet the rules for homes being sold, rented or hired.
- Only a licensed electrician can connect or replace hardwired alarms.
Renting in Western Australia
Landlords and property managers must:
- have compliant alarms in place before a tenancy or hire starts; and
- keep them working, wired and in date (Building Regulations 2012, reg 62).
Tenants should:
- test the alarms monthly and report faults;
- change an easy-to-reach 9V backup battery when needed.
Penalties: Owners face up to $5,000 per offence, or a $1,000 infringement notice for not having compliant alarms before a sale, tenancy or hire.
What the fire service recommends
DFES recommends mains-powered photoelectric alarms wherever possible, or 10-year lithium alarms where hardwiring isn’t possible, interconnected so they all sound together. It suggests alarms in every bedroom, living room, hallway, stairway and garage, and testing them monthly. This is advice, not the legal minimum.
Buying smoke alarms for a home in Western Australia
- Selling or leasing? Get mains-powered alarms fitted by a licensed electrician before settlement or the lease starts.
- Concrete ceiling or no space to run wires? A 10-year battery alarm may be allowed, or ask your council.
- DFES recommends photoelectric, interconnected alarms in bedrooms, living areas and hallways.
We deliver smoke alarms Australia-wide. Browse the shop or contact us for help choosing.
Western Australia smoke alarm questions
Do I need hardwired smoke alarms to sell a house in WA?
Yes, as a rule: alarms must be permanently wired to mains power before the sale. 10-year battery alarms are allowed only in limited cases.
What’s the fine in WA?
Up to $5,000 per offence, or a $1,000 infringement notice.
Sources
- WA Government, “Smoke alarm laws: homes being sold, rented and hired” (checked 19 Nov 2026)
- DFES, “Smoke alarms” (checked 19 Nov 2026)
- Consumer Protection WA, “Rental home safety” (checked 19 Nov 2026)
- Building and Energy, short-term rental smoke alarm bulletin (PDF) (checked 19 Nov 2026)
General information, not legal advice. The rules for your home depend on when it was built, whether it’s rented, and your local council.